Clinically Trusted and Proven Devices Clinically Trusted and Proven Devices Clinically Trusted and Proven Devices Clinically Trusted and Proven Devices Clinically Trusted and Proven Devices

Shopping cart

Subtotal $0.00

View cartCheckout

Celosia™ Covered Stent

  • Home
  • Celosia™ Covered Stent

Celosia™ Covered Stent

ShapeCovered Stent

Celosia™ Covered Stent

CELOSIA™ HAS YOU COVERED.
The Celosia Coronary Covered Stent is indicated for use in the treatment of free perforations, defined as free contrast extravasation into the pericardium, in native coronary vessels ≥2.25mm in diameter.

CELOSIA - CASE STUDIES

An ideal device for emergency use situations.

  • Optimal trackability and deliverability in the tortuous anatomy
  • Excellent flexibility and superior navigability in challenging lesions
  • ePTFE polymer with proprietary micro-porous technology
  • Mono layer graft stent with a U.S. Patented intravascular hybrid open-closed cell design
  • Superior vessel conformance
  • Optimum radial strength
  • Lowest pre-mounted crimped profile

*Also marketed in certain countries as Direct-Stent Stent Graft.

Celosia™ — Product Specifications

SpecificationDescription
Stent DesignDirect-Stent² — Patented Hybrid Cell Design, Stent Ends Flarable
Stent MaterialL605 Cobalt Chromium Alloy
Stent Covering PolymerePTFE Microporous Polymer, IND 90–120 μm
Wall Thickness0.08 mm / 0.003 in
Balloon SystemRx Rapid Exchange Balloon Catheter
Balloon MaterialSemi-Compliant — Nylon Blend
Optimal Deployment Pressure10 ATM
Nominal Pressure**10 ATM
Rated Burst Pressure16 ATM
Shaft Size (Proximal/Distal)2F / 2.7F
Minimum Guiding Catheter*5F (2.25–3.5 mm diameter); 6F (4.0–6.0 mm diameter)
Crimped Profile1.0–1.4 mm
Tip Entry Profile0.017 in
Recommended Guidewire0.014 in
Delivery Catheter Length142 cm
Stent Length10–30 mm
Stent Ends Flaring2.25, 2.5, 2.75 → 3.5 mm;
3.0–4.5 → 5 mm;
5.0, 6.0 → 7 mm
Radial Force3–2.5 mm | 13 N force

* See individual manufacturer for guide catheter Fr equivalent.

** Assure full deployment of stent. Deployment pressures should be based on lesion characteristics.

Ordering Information

Stent Diameter (mm)Stent Length (mm)
2.2510, 13, 16, 19, 23, 26
2.510, 13, 16, 19, 23, 26, 30
2.7510, 13, 16, 19, 23, 26, 30
3.010, 13, 16, 19, 23, 26, 30
3.510, 13, 16, 19, 23, 26, 30
4.010, 13, 16, 19, 23, 26, 30
4.515, 19, 23, 26, 30
5.017, 20, 27
Ordering number: 76 + Stent Diameter + Stent Length
Example: diameter 2.25 mm, length 10 mm → 7622510
Footer Section